JUMO TYA-432 thyristor power switch (709010)
image_709010

  • Load currents 25A, 50A
  • Load voltages 265V, 530V
  • Control voltage 4...32V DC
  • Without heat sink

JUMO TYA-432 Halvledarrelä (70.9020)
image_709020 UL / CRUUS Prüfzeichen

  • Lastström 20A, 30A, 45A
  • Lastspänning 265V, 660V
  • Styrspänning 4...32V DC
  • 1-fas och 3-fasutförande
  • Med kylfläns
     

JUMO TYA-110 thyristor power unit (709040)
image_709040

  • Load currents up to 250A
  • Load voltages 24V to 500V
  • Mounted on rail and wall-mounted
  • Phase-angle mode and burst-firing mode

JUMO IPC IGBT Power Converter (709050)
image_709050

  • Load currents 70 A, 100 A, 200 A
  • Load voltages up to 380 V DC
  • Wall mounting
  • Patented control procedure
  • Amplitude control
  • Direct control of low voltage heating elements (SIC, MoSi2)

JUMO TYA 201 - Single-Phase Power Controller (709061)
image_709061

  • Easy configuration of the device through plain text display
  • Setup program for configuration via USB interface
  • Transmission of the setup data is possible even without voltage supply to the device (supply through USB port)
  • Network load optimization through dual energy management
  • RS422/485 interface or PROFIBUS-DP
  • Generalized phase control, burst-firing mode, and half-wave control
  • Soft start function with current limiting
  • Resistance monitoring and limitation for MoSi2 heating elements
  • Teach-in function to detect partial load failure
  • Integrated diagnosis systems (e.g. rotating field detection)

JUMO TYA 202 - Three-phase Power Controller in Three-phase Economy Circuit (709062)
image_709062

  • Easy configuration of the device through plain text display
  • Setup program for configuration via USB interface
  • Transmission of the setup data is possible even without voltage supply to the device (supply through the USB port)
  • Network load optimization through dual energy management
  • RS422/485 interface or PROFIBUS-DP
  • Burst firing mode
  • Softstart function with current limiting
  • Resistance monitoring and limitation for MoSi2 heating elements
  • Teach-in function to detect partial load failure
  • Integrated diagnosis systems such as rotary-field detection